ZCM 102 - KW 1,88 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 102 - KW 1,88 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. The smallest model, ZCM 102 using the refrigerant R134a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 1,88 Absorbed compressor power = kW 0,61 Refrigerant gas = R134a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pressure kPa 302 Cooling medium circulation = m³/h 0,32 Pump pressure = bar 3 5 - 6 - kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 63 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCM 103 - KW 2,99 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 103 - KW 2,99 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 2,99 Absorbed compressor power = kW 0,61 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pump pressure kPa 276 Cooling medium circulation = m³/h 0,51 Pump pressure = bar 3 5 - 6 kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 95 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCM 104 - KW 3,92 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 104 - KW 3,92 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 3,92 Absorbed compressor power = kW 0,87 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pump pressure kPa 229 Cooling medium circulation = m³/h 0,67 Pump pressure = bar 3 5 - 6 kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 97 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCM 105 - KW 4,70 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 105 - KW 4,70 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 4,70 Absorbed compressor power = kW 0,99 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pump pressure kPa 186 Cooling medium circulation = m³/h 0,81 Pump pressure = bar 3 5 - 6 kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 100 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCM 106 - KW 5,47 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 106 - KW 5,47 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 5,47 Absorbed compressor power = kW 1,17 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pump pressure kPa 191 Cooling medium circulation = m³/h 0,94 Pump pressure = bar 3 5 - 6 kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 105 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCM 107 - KW 5,99 ZCM refrigeration unit with a battery of air condensation for indoor installation (preferred) or outside
ZCM 107 - KW 5,99 ZCM refrigeration unit with a battery of air condensation. Each unit is made in cooling only version, for indoor installation (preferred) or outside, excellent to meet the needs of having cold water to cool industrial processes. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 5,99 Absorbed compressor power = kW 1,36 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P3 pump pressure kPa 168 Cooling medium circulation = m³/h 1,030 Pump pressure = bar 3 5 - 6 kW 0,30 Stainless steel water tank = l 25 Electrical supply = Ph/V/Hz 1/230/50-60 Tube diameter = Rp 1/2“ Fans = 1 Fan Weight net = kg 105 Dimensions length x width x height = mm 630 x 570 x 954 The ZCM is a range of air cooled water chillers for process cooling application. Each unit is made in cooling version only, for indoor installation (preferred) or outside, good to meet the needs of getting cold water for cooling the industrial water processes. The complete range consists of several models with a cooling capacity from 2 to 7 kW. The model name is ZCF 102, 103, 104, 105, 106 and 107. Each unit has been designed with passion, love and with all our deep experience in the industrial process sector. The final result is offer each standard unit complete in the standard version with several (let’s say) "options" which are standard for us, so offer in this way each ZCF reliable, robust, efficient. Again the passion and experience in the process cooling sector has allowed to design the whole range by choosing only reliable and proven components, everything has been designed by our engineers, again we can offer all in compact overall dimensions. Each ZCF has tested in all the part as condensing and evaporating temperatures, freezing temperature, gas equalization during the various phases of work. We can really provide an efficient range, silent, versatile and reliability. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The ZCM series of units are simple but at the same time equipped with all the main component. The refrigerant circuit is to compost component of primary brands to ensure the best product quality. The cooling circuit uses copper pipes with the highest quality in the market. All pipes are twice tested to prevent any refrigerant gas leaks while protecting the environment. The cooling circuit can be viewed and opened for maintenance work from various angles: the front and side. The panels are extracted simply by unscrewing four screws that hold the side panels. This way you have complete access to the entire cooling circuit and in its entirety. The refrigerant circuit is complete with standard thermostatic valve, which increases efficiency in all fields of work to which the unit may be affected (in the market 99% of the competitors enter the capillary instead of the thermostat valve to reduce costs , but the capillary is an excellent component for work to a limited field of application). OPTION INCLUDED IN STANDARD RANGE: · Thermostatic valve · High pressure switch ü Coaxial copper exchanger dipped in the water tank. ü Hermetic rotary compressors ü Microprocessor control for a complete management of all the components and functions of the unit. ü R410a refrigerant gas which enhances the performance, efficiency and ease of care in the event of losses (only the first model ZCM 102 works with R134a) ü thermostatic valve for improving the operation (cooling capacity and efficiency) of the unit to the various and different workloads ü Cooling circuit made with top quality materials, assembled by trained personnel, tested in all parts ü Refrigerant manometers and water gauge ü High pressure switch ü complete with antifreeze sensor to prevent breakage due to freezing water The compressor is the component that compresses the refrigerant gas from the evaporator, and sends it to the high pressure condenser. The condenser is an heat exchanger consisting of a coil made of copper tubes and aluminium fins that allow the heat exchange between refrigerant and air gases. Inside the exchanger gas condensate transferring the condensation heat from the refrigerant gas to air (which flows outside and passes through the battery). The condensing coil inserted in the back of the cooling unit opposite to the electrical panel. OPTION INCLUDED IN STANDARD RANGE: Metallic Air filter in front of the condensing coil The ZCM series mounts rotary compressor characterized by low noise and low vibration. Furthermore, the compressor is able to work in wide operating ranges while still maintaining a good reliability in time. The compressor is electrically protected to prevent too many ON / OFF in the hour to maintain its reliability and by a gas equalization system. The fans of ZCM range are axial type, inserted inside carpentry to reduce noise and the overall size of the unit. The fan draws air from the outside by passing through the condensing coil, all protected by an air filter. OPTION INCLUDED IN STANDARD RANGE: ü Aanti-vibration pads under the compressor ELECTRICAL CIRCUIT The electrical board is built and wired according to the Low Voltage Directive 2006/95/EC, the standard EN 60204-1 and Electromagnetic directive EMC 89/336. The switchboard is complete with a main switch and a closing door locks to ensure access to the framework by experts in the field. It is made by top brand components. On the door of the electrical panel is located the microprocessor control that allows the start of the refrigeration unit, the setting of the water temperature, the display of any alarms. The door of the electrical panel is recessed relative to the structure so as not to expose it to damage due to improper handling of the unit. The degree of the frame protection is IP 44.The standard power supply is 230/1/50. The wiring diagram is inside the unit in the control cabinet. It has also the complete list of coded spare parts so as to help the client at any time. Replacement parts are available in stock CF CHILLER FRIGORIFERI or from our distributors. The electrical circuit is placed in a dedicated area separate from the cooling and the hydraulic circuit. In this way, the maintenance and service work can be done by a specialist even though it has no competence in the cooling and hydraulic material. ü Microprocessor control card ZCM control unit is equipped with a microprocessor control by DIXELL The control has the following functions: ü ccompressor Set for ensuring the constancy of the temperature of the water produced; ü ooperation of the pump; ü Hhigh pressure prevention alarm; ü Electrical panel with main switch and closing with door lock - Power supply 230V/1 Phase 50/60 cycles HYDRAULIC CIRCUIT The hydraulic circuit mainly consists of; pump, water tank, water level display, manual water loading and bypass water. The tank is of the type in stainless steel, the entire hydraulic circuit is of the type NO FERROUS. The accumulation tank it can be filled with water with water thanks to the presence of a manual loading place in the roof unit. The water level in the tank is easily visible thanks to a plastic viewer with inside a red ball. In this viewer are placed the minimum and maximum water levels. It 'also the pump that is placed in the back (inside carpentry) complete with a water manometer to see the prevalence of the same. This allows an easy hydraulic installation, just connect the two water pipes, one input and one output. Everything is simplified by the presence of stickers that indicate well what are the inlet and outlet pipes ü 25-liter insulated water tank storage made in stainless steel. The tank is suitable for open hydraulic circuits. o water tank is suitable to be inspected and maintainable ü NO FERROUS water circuit ü Water filling kit complete manual water level viewer ü Calibrate water by-pass ü Peripheral pump with brass impeller. ü Water pressure gauge for easy viewing of the pressure ü Antifreeze sensor ü LLabels on the unit for avoiding any wrong connection ALWAYS INCLUDED ü Each unit comes standard with a filter capacitor, easy to clean and useful to prevent soiling the condensing coil. Each unit is complete with the following documentation: • Operation and maintenance of the unit • Electrical Wiring diagram • Cooling circuit scheme • Dimensional drawing This paper documentation is place inside into the electrical box within the framework of each unit. Also, after the sale of documentation are provided is provided in pdf format to each customer so you can always have a copy in electronic format, Our service is always available for any kind of help or suggestions technician by phone or by mail The service is also available for maintenance and control units or to arrange a maintenance program scheduled chiller where specified under the contract of sale or if agreed later WORKING FIELD ü Water temperature -5°C / +30°C ü Cooling temperature from 10°C / +45°C (on request, water and ambient temperature down to -10°C) TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 108 - KW 7.9 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 108 - KW 7.9 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 7,9 Absorbed compressor power = kW 1,52 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 153/296/380/484 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 60 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 3,0 FLA = A 6,0 Tube diameter = Rp 1“ Fans = 1 Fan diameter = mm 350 Fan nominal power = KW 0,17 Weight net = kg 175 Dimensions length x width x height = mm 926 x 690 x 1173 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 110 - KW 9,5 series represents a range of air cooled chiller suitable for outdoor installation
ZCF 110 - KW 9,5 series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 9,5 Absorbed compressor power = kW 2,03 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 139/271/354/451 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 60 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 3,0 FLA = A 5,0 Tube diameter = Rp 1“ Fans = 1 Fan diameter = mm 350 Fan nominal power = KW 0,17 Weight net = kg 180 Dimensions length x width x height = mm 926 x 690 x 1173 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 117 - KW 16,3 series represents a range of air cooled chiller suitable for outdoor installation
ZCF 117 - KW 16,3 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 16,3 Absorbed compressor power = kW 3,19 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 140/190/304/406 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 60 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 5,3 FLA = A 9,9 Tube diameter = Rp 1“ Fans = 1 Fan diameter = mm 350 Fan nominal power = KW 0,17 Weight net = kg 185 Dimensions length x width x height = mm 926 x 690 x 1173 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 115 - KW 14,7 series represents a range of air cooled chiller suitable for outdoor installation
ZCF 115 - KW 14,7 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 14,7 Absorbed compressor power = kW 2,74 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 183/294/371/506 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 100 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 5,3 FLA = A 9,9 Tube diameter = Rp 1“ Fans = 2 Fan diameter = mm 350 Fan nominal power = KW 0,34 Weight net = kg 230 Dimensions length x width x height = mm 1460 x 735 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 120 - KW 18.9 series represents a range of air cooled chiller suitable for outdoor installation
ZCF 120 - KW 18.9 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 18,9 Absorbed compressor power = kW 4,06 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 166/277/356/488 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 100 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 6,0 FLA = A 11,0 Tube diameter = Rp 1“ Fans = 2 Fan diameter = mm 350 Fan nominal power = KW 0,34 Weight net = kg 240 Dimensions length x width x height = mm 1460 x 735 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 125 - KW 24,8 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 125 - KW 24,8 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 24,8 Absorbed compressor power = kW 5,75 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 140/251/333/459 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 100 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 9,0 FLA = A 15,0 Tube diameter = Rp 1“ Fans = 2 Fan diameter = mm 350 Fan nominal power = KW 0,34 Weight net = kg 255 Dimensions length x width x height = mm 1460 x 735 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 127 - KW 27,3 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 127 - KW 27,3 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 27,3 Absorbed compressor power = kW 6,3 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 140/250/323/450 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 100 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 9,9 FLA = A 16,5 Tube diameter = Rp 1“ Fans = 2 Fan diameter = mm 350 Fan nominal power = KW 0,34 Weight net = kg 275 Dimensions length x width x height = mm 1460 x 735 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 130 - KW 29,1 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 130 - KW 29,1 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 29,1 Absorbed compressor power = kW 6,43 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 151/236/319/441 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 11,0 FLA = A 19,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 350 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 135 - KW 33,8 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 135 - KW 33,8 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 33,8 Absorbed compressor power = kW 7,21 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 130/211/296/412ooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 12,0 FLA = A 21,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 365 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 140 - KW 38,2 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 140 - KW 38,2 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 38,2 Absorbed compressor power = kW 8,84 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 131/209/295/405 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 14,0 FLA = A 23,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 380 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 145 - KW 43,5 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 145 - KW 43,5 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 43,5 Absorbed compressor power = kW 8,89 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 136/238/305/428 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 15,0 FLA = A 25,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 460 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 150 - KW 52,3 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 150 - KW 52,3 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 52,3 Absorbed compressor power = kW 9,75 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 131/234/298/418 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 16,0 FLA = A 28,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 480 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 155 - KW 58,5 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 155 - KW 58,5 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 58,5 Absorbed compressor power = kW 11,92 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 101/204/266/380 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 200 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 18,0 FLA = A 32,0 Tube diameter = Rp 1 1/2“ Fans = 2 Fan diameter = mm 500 Fan nominal power = KW 1,40 Weight net = kg 560 Dimensions length x width x height = mm 1900 x 910 x 1450 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 1070 - KW 63,9 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 1070 - KW 63,9 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 63,9 Absorbed compressor power = kW 11,92 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 318/391/488/632 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 300 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 25,7 FLA = A 42,9 Tube diameter = Rp 2“ Fans = 2 Fan diameter = mm 710 Fan nominal power = KW 2,30 Weight net = kg 610 Dimensions length x width x height = mm 2700 x 1100 x 1980 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 1080 - KW 77,0 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 1080 - KW 77,0 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 77,0 Absorbed compressor power = kW 13,59 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 298/370/457/610 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 300 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 29,1 FLA = A 49,1 Tube diameter = Rp 2“ Fans = 2 Fan diameter = mm 710 Fan nominal power = KW 2,30 Weight net = kg 630 Dimensions length x width x height = mm 2700 x 1100 x 1980 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 1090 - KW 85,7 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 1090 - KW 85,7 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 85,7 Absorbed compressor power = kW 16,02 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 295/366/464/606 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 300 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 31,5 FLA = A 52,7 Tube diameter = Rp 2“ Fans = 2 Fan diameter = mm 710 Fan nominal power = KW 2,30 Weight net = kg 645 Dimensions length x width x height = mm 2700 x 1100 x 1980 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 1100 - KW 91.8 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 1100 - KW 91.8 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 63,9 Absorbed compressor power = kW 19,1 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 284/354/452/594 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 300 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 34,9 FLA = A 58,7 Tube diameter = Rp 2“ Fans = 2 Fan diameter = mm 710 Fan nominal power = KW 2,30 Weight net = kg 675 Dimensions length x width x height = mm 2700 x 1100 x 1980 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request
ZCF 1120 - KW 108,1 ZCF series represents a range of air cooled chiller suitable for outdoor installation
ZCF 1120 - KW 108,1 ZCF series represents a range of air cooled chiller suitable for outdoor installation thanks to IP54 protection. The range is suitable to work both in process cooling and in air conditioning. All the range has been designed, manufactured and tested to work with the new ecological refrigerant gas R410a. Cooling capacity at water temperature 15 °C out and water temperature in 20 °C ambient temperature 25 °C = kW 108,1 Absorbed compressor power = kW 22,40 Refrigerant gas = R410a Refrigerant medium = water ambient temperature = from °C +15 until +45 Regrigerant temperature = from °C +8 until +25 K stability ±1 Pumps P2/P3/P4/P5 pumps pressure kPa 267/334/432/574 Cooling medium circulation = m³/h on request Pump pressure = bar 3 5 - 6 Stainless steel water tank = l 300 Electrical supply = Ph/V/Hz 3/400/50 FLI = kW 39,3 FLA = A 69,7 Tube diameter = Rp 2“ Fans = 2 Fan diameter = mm 710 Fan nominal power = KW 2,30 Weight net = kg 690 Dimensions length x width x height = mm 2700 x 1100 x 1980 The entire series is composed by a great number of models with cooling power from 7 to 110 kW; it has been optimized to have high energy efficiency performances, installation handiness, easy in maintenance operations, even ordinary and extraordinary. Each model of the series is manufactured and assembled with main brands components, to offer a very high quality product, great efficiency and reliability. Furthermore the range has been designed to make easier maintenance and technical assistance operations, according to European directives Each chiller is composed by 3 different circuits: cooling, hydraulic and electric circuit. In this range each circuit is designed and assembled inside a speci????c and free standing area, separated from the others. The main advantage is the possibility to operate on the desired circuit and making on it technical assistance or maintenance according to one’s own competences. Standard color is RAL 9018. On request it is possible to have different or particular RAL colors. COOLING CIRCUIT The refrigerant circuit is made in a simple and straightforward way to reduce any kind of problem. The cooling circuit is full of components of leading premium brands. Each component is connected with copper pipes of high thickness, tested and proven internally and externally, to give it a dual guarantee to the product itself. The refrigerant circuit designed and engineered in 3D is simple and compact, offers the possibility to be easily repaired in every point thanks to the possibility to supply assembly kits where necessary. ELECTRICAL BOARD The electrical panel is generous in size, placed inside a special housing made in carpentry. Each cable in the electrical panel is numbered and connected to terminal strip, complete with electrical drawing put inside the unit that simpli????es the connections understanding. Complete with circuit breakers to protect the major organs of the chiller, the control section is composed of a microprocessor card with an external interface. Each board is equipped with a locking device port. The standard power supply is 400/3/50 Options: - Power supply 460/3/60 HYDRAULIC MODULE Our range has the ability to be able to be complete or less of the hydraulic unit. Therefore, the hydraulic unit is always an option which may or may not be required depending on the type of plant. The hydraulic unit can be configured in different ways: 1. No water tank and no pump: 2. Only tank 3. Only pump 4. Water tank and Pump 5. Water tank and double pump TESTING Each chiller is tested in testing room. During the testing phase are tested operating data: - Proper mounting of components - Fixing all components - Product control according to safety standards - Electrical test in accordance with EN60204 - Operation of the control board - Chiller performances in standard conditions - Check setting of the microprocessor board Industrial liquid chillers are built for industrial cooling, where they cool products, mechanisms and factory machinery in processes such as plastic injection molding, blow molding, metalworking, welding, die casting, chemical and pharmaceutical processing, food and beverage processing, lab equipment and lasers. · Plastics Industry: The plastics industry uses ZCM & ZCF to reduce cycle times in injection moulding and blow moulding by regulating temperatures · Automotive Industry: ZCM & ZCF can be uses for cooling spindle motors, hydraulics, automation drivers & welders. · Baking Industry: The baking industry may uses ZCM & ZCF for their process of mixing. The chilled water from a water chiller may be used to allow longer mixing times which improves the final quality for any grade of flour. · Food Industry: The food industry uses ZCM & ZCF to cool any process such as chocolate manufacturing, vegetable processing, meat massagers/injectors and confectionary manufacturing. · Beverage Industry: Wine, Beer, spirits , etc… need to be cool in their fermentation and treatment process · Packaging Industry: ZCM & ZCF good for the cooling of the automation system in this type of machinery · Pharmaceutical Industry: The heat from emollient vats needs to go somewhere. ZCM & ZCF helps pharmaceutical companies save money by reducing the total manufacturing time, leading to cost savings in labour costs. · Printing Industry: ZCM & ZCF can be used to regulate temperatures in presses and rollers which leads to reduction of stretching and bleeding. This in turn decreases the time needed to print which improves efficiency and leads to higher quality products at a cost savings. ZCM & ZCF can be very useful also for ink cooling and lamp cooling. · Biogas Industry: Before the gas can be used for the production of electricity and heat in a “Combined Heat & Power Unit(CHP)”, biogas treatment in the form of filtration via a biogas filter, preceded by a heat-exchanger must take place. So you combine the ZCM & ZCF range. · Recycling Industry: mixing, thermos treatment uses for the process. · Wastewater Treatment: ZCM & ZCF to cool down pump drives · Other industries that benefit from the uses of a ZCM & ZCF include boat & airplane manufacturing, metal finishers (every type of tool machine…), skating rinks, chemical industry, composite manufacturers, laser cutting machines, dry cleaners…
Price on request